linkcom manufacturing co., ltd *,# =see notes below model specification ** * * * * (6)load regulation measured from 2 0% to full load. (7)line regulation measured from 1 00vac to 277vac. (8)preset accuracy measured at nor mal load, 120vac input. reference high operating ambient temp: -30 ~+70 (refer to output dreating curve) dimension (l*w*h): 8.2 * 2.83 * 1.52 inch input frequency 88% hold up time dc output power input voltage range 25ms at full load 115vac/230vac 90-305vac, 127-431vdc, normal 100-277vac load regulation (%) *(6) power factor:>0.98@115vac;>0.95@230vac;@full load safety: ul / tuv / cb / pse emc: ce / fcc comply with indoor/outdoor waterproof (ip 67) preset accuracy (%) *(8) o/p noise (p-p, mv) *(3) 1.7a/115vac 0.65a/230vac 0.03% / (0-50 , typ) over temp. protection storage temperature -30 to +70 (refer to output dreating curve) emi withstand voltage leakage current inrush current (typ) active power factor efficiency(typ @full load) setup,rise time(typ.) line regulation (%) *(7) (9)100% production tested. (5)minimum load is not required fo r proper operation . notes (1)all parameters not specially mentioned are measu red 230vac input. (2)all specifications typical @25 , unless otherwise noted, at normal line and load. (3)ripple and noise measured direc tly at pins/terminals at nom. load, 0.1uf bypass an d 47uf electrolytic, pk-pk @20mhz bandwidth. (4)specified for free-air convecti on cooling. -40 to +80 operating temp.*(4) temp. coefficient shut down and latch off o/p voltage , re-power on t o recover over current protection safety relative humidity over v, protection pf>0.98 @115vac, pf>0.95@230vac at full load and ra ted output voltage cold start 65a @ 230vac 120%~160% rated output power ; hiccup mode <0.45ma/264vac ac current 10 to +90%, non-cond. short circuit protection module : lcvh-100 120 features output current(a) *(5) rohs compliant lcvh-100 120 norm. 12 max. min. ac input 90~305vac 96 w power supply 208.4 * 72 * 38.55 mm 8.2 * 2.83 * 1.52 inch model name size dimension (l*w*h): 208.4 * 72 * 38.55 mm model no. part no. lcvh-100 120 plcvh1100 120 *(9) 11 dc output voltage (v) 8 1 ul 60950-1 / tuv en61347-2-13 / cb / pse short circuit protection will restart automatically after the fault condition is removed range:47-63hz, normal 50-60hz 250 2000ms,500ms at full load 115vac/230vac protection: ovp / otp / scp / ocp ce en55015 / fcc part15 i/p-o/p 3.75kvac, o/p-grnd 0.5kvac, i/p-grnd 1.88kvac isolation resistance dimensions(l*w*h) 208.4 * 72 * 38.5 mm 8.2 * 2.83 * 1.52 inch i/p-o/p, i/p-fg,o/p-fg :100m ohms / 500vdc / 25 / 70% rh www.linkcom.com.tw for more information, please contact with: sales@ linkcom.com.tw
linkcom manufacturing co., ltd power supply 208.4 * 72 * 38.55 mm 8.2 * 2.83 * 1.52 inch model name size model no. part no. lcvh-100 120 plcvh1100 120 reference unit :mm inch dimensions derate www.linkcom.com.tw for more information, please contact with :sales @ linkcom.com.tw
|