  linkcom manufacturing co., ltd *,# =see notes below model specification ** * * * * (6)load regulation measured from 2 0% to full load. (7)line regulation measured from 1 00vac to 277vac. (8)preset accuracy measured at nor mal load, 120vac input. reference high operating ambient temp: -30 ~+70 (refer to output dreating curve) dimension (l*w*h): 8.2 * 2.83 * 1.52 inch input frequency 88% hold up time dc output power input voltage range 25ms at full load 115vac/230vac 90-305vac, 127-431vdc, normal 100-277vac load regulation (%) *(6) power factor:>0.98@115vac;>0.95@230vac;@full load safety: ul / tuv / cb / pse emc: ce / fcc comply with indoor/outdoor waterproof (ip 67) preset accuracy (%) *(8) o/p noise (p-p, mv) *(3) 1.7a/115vac 0.65a/230vac 0.03% / (0-50 , typ) over temp. protection storage temperature -30 to +70 (refer to output dreating curve) emi withstand voltage leakage current inrush current (typ) active power factor efficiency(typ @full load) setup,rise time(typ.) line regulation (%) *(7) (9)100% production tested. (5)minimum load is not required fo r proper operation . notes (1)all parameters not specially mentioned are measu red 230vac input. (2)all specifications typical @25 , unless otherwise noted, at normal line and load. (3)ripple and noise measured direc tly at pins/terminals at nom. load, 0.1uf bypass an d 47uf electrolytic, pk-pk @20mhz bandwidth. (4)specified for free-air convecti on cooling. -40 to +80 operating temp.*(4) temp. coefficient shut down and latch off o/p voltage , re-power on t o recover over current protection safety relative humidity over v, protection pf>0.98 @115vac, pf>0.95@230vac at full load and ra ted output voltage cold start 65a @ 230vac 120%~160% rated output power ; hiccup mode <0.45ma/264vac ac current 10 to +90%, non-cond. short circuit protection module : lcvh-100  120 features output current(a) *(5) rohs compliant lcvh-100  120 norm. 12 max. min. ac input 90~305vac 96 w power supply 208.4 * 72 * 38.55 mm 8.2 * 2.83 * 1.52 inch model name size dimension (l*w*h): 208.4 * 72 * 38.55 mm model no. part no. lcvh-100  120 plcvh1100  120 *(9) 11 dc output voltage (v) 8 1 ul 60950-1 / tuv en61347-2-13 / cb / pse short circuit protection will restart automatically after the fault condition is removed range:47-63hz, normal 50-60hz 250 2000ms,500ms at full load 115vac/230vac protection: ovp / otp / scp / ocp ce en55015 / fcc part15 i/p-o/p 3.75kvac, o/p-grnd 0.5kvac, i/p-grnd 1.88kvac isolation resistance dimensions(l*w*h) 208.4 * 72 * 38.5 mm 8.2 * 2.83 * 1.52 inch i/p-o/p, i/p-fg,o/p-fg :100m ohms / 500vdc / 25 / 70% rh www.linkcom.com.tw for more information, please contact with: sales@ linkcom.com.tw
linkcom manufacturing co., ltd power supply 208.4 * 72 * 38.55 mm 8.2 * 2.83 * 1.52 inch model name size model no. part no. lcvh-100  120 plcvh1100  120 reference unit :mm inch dimensions derate www.linkcom.com.tw for more information, please contact with :sales @ linkcom.com.tw


▲Up To Search▲   

 
Price & Availability of LCVH-100X120

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X